Skip to main content
Image
Stock image UAV drone monitoring gas near pipeline valves

LLNL researchers have developed a TDLAS-based, standalone, real-time gas analyzer in a small form-factor for continuous or single-point monitoring.  The system can analyze multiple gases with ultra-high sensitivity (ppm detection levels) in harsh conditions when utilizing wavelength-modulation spectroscopy (WMS). 

Image
Flue Gas Emissions a Major Source of Atmospheric CO2

This invention solves a limitation in the current practice of adding hydroxyl functional groups to the aminopolymer through the use of an alternative synthetic approach. The novelty of our approach is to produce new structurally modified relatives of common aminopolymers (PEI and PPI) as well as new functionalized materials in which the hydroxyl groups are tethered to a carbon in the backbone…

Image
Schematic of 2P3C setup.  Pump laser component is in red while probe laser component is denoted in blue.

LLNL’s novel approach combines 2-color spectroscopy with CRDS, a combination not previously utilized.

Image
Cross Section of the High-Voltage Insulator Joint

The approach is to build a high voltage insulator consisting of two materials:  Poly-Ether-Ether-Ketone (“PEEK”) and Machinable Ceramic (“MACOR”).  PEEK has a high stress tolerance but cannot withstand high temperatures, while MACOR has high heat tolerance but is difficult to machine and can be brittle.  MACOR is used for the plasma-facing surface, while PEEK will handle the stresses and high…

Image
Microcapsules offer high surface area and a superior delivery system.

This invention describes a multiple nozzle microfluidic unit that allows simultaneous generation streams of multiple layered coaxial liquid jets. Liquids are pumped into the device at a combined flow rate from 100 mL/hr to 10 L/hr. Droplets are created with diameters in the range of 1 µm to 5 mm and can be created with 1-2 shell layers encapsulating fluid. Droplets created from the system can…

Image
An artist’s concept rendering of a 3.5-meter linear induction accelerator (LIA) with four lines-of-sight toward a patient. The blue elements magnetically focus and direct the LIA’s electron beams.

LLNL’s approach is to use their patented Photoconductive Charge Trapping Apparatus (U.S. Patent No. 11,366,401) as the active switch needed to discharge voltage across a vacuum gap in a particle accelerator, like the one described in their other patent (U.S. Patent No.

Image
Graphic of NMR

There are prominent technical challenges arising from spinning a battery on the order of kilohertz as required by magic angle spinning in order to obtain spectral resolution that are addressed and enable operando solid-state NMR. The operando NMR measurement allows for continuous monitoring of the battery components and of potential metastable states that may exist during…