A thyristor will stay conducting until the current through the device is zero (“current zero”) or perhaps slightly negative. LLNL’s approach is to use the opticondistor (“OTV”) to force this current zero in order to force the device into an “off” state. By combining a light-activated thyristor with an OTV, a noise-immune, high efficiency, high-power switching device can be constructed. The…
Keywords
- Show all (52)
- Imaging Systems (9)
- Photoconductive Semiconductor Switches (PCSS) (9)
- Semiconductors (6)
- Optical Switches (4)
- Power Electronics (3)
- Sensors (3)
- Computing (2)
- MEMS Sensors (2)
- Optical Sensors (2)
- Particle Accelerators (2)
- Spectrometers (2)
- 3D Electronics (1)
- Analysis (1)
- Precision Engineering (1)
- (-) Electric Grid (2)
- (-) Additive Manufacturing (1)
- (-) Quantum Science (1)
- (-) Simulation (1)
![LLNL energy grid protection device](/sites/default/files/styles/scale_exact_400x400_/public/2023-10/LLNL%20energy%20grid%20protection%20device_0.png?itok=vpqzRY_R)
The approach is to leverage the fact that a momentary “load” equal to the power transmission line impedance, (Z0), during the transient can suppress its propagation. Z(0) is typically a fixed impedance of several hundred ohms based on the geometry of most single wire transmission lines.
So, an isolated self-powered opticondistor (OTV) system may provide an ultrafast method of…
![LLNL has developed a new method for increasing lifetime in quantum coherent devices.](/sites/default/files/styles/scale_exact_400x400_/public/2020-09/Quantum%20Coherent%20Devices.gif?itok=kv1ZYIim)
LLNL has developed a method of extending device lifetimes by imprinting into the device a shape that excludes specific vibrational modes, otherwise known as a phononic bandgap. Eliminating these modes prevents one of the primary energy loss pathways in these devices. LLNL’s new method enhances the coherence of superconducting circuits by introducing a phononic bandgap around the system’s…
![multichannel_pyrometer.jpg multichannel_pyrometer](/sites/default/files/styles/scale_exact_400x400_/public/2019-08/multichannel_pyrometer.jpg?itok=x0sCe_BN)
LLNL researchers have designed and tested performance characteristics for a multichannel pyrometer that works in the NIR from 1200 to 2000 nm. A single datapoint without averaging can be acquired in 14 microseconds (sampling rate of 70,000/s). In conjunction with a diamond anvil cell, the system still works down to about 830K.
![Intrinsic Use Control](/sites/default/files/styles/scale_exact_400x400_/public/2022-06/Intrinsic%20Use%20Control.jpg?itok=plVEiBwC)
LLNL's method of equivalent time sampling incorporates an embedded system that generates the pulses used to trigger the external circuit and the data acquisition (DAQ). This removes the external reference clock, allowing the overall system clock rate to change based on the ability of the embedded system. The time delays needed to create the time stepping for equivalent time sampling is done by…
![Spectroscopic Injection Pulser prototype](/sites/default/files/styles/scale_exact_400x400_/public/2022-06/Spectroscopic%20Injection%20Pulser%20prototype%20.jpg?itok=CQZmEGas)
The technology that is available has the capability to inject realistic radiation detection spectra into the amplifier of a radiation detector and produce the all the observables that are available with that radiation detection instrument; count-rate, spectrum, dose rate, etc.
The system uses the capability of LLNL to generate the source output for virtually any source and determine…