LLNL researchers have developed a TDLAS-based, standalone, real-time gas analyzer in a small form-factor for continuous or single-point monitoring. The system can analyze multiple gases with ultra-high sensitivity (ppm detection levels) in harsh conditions when utilizing wavelength-modulation spectroscopy (WMS).
Keywords
- Show all (75)
- Imaging Systems (9)
- Photoconductive Semiconductor Switches (PCSS) (9)
- Electric Grid (8)
- Carbon Utilization (6)
- Semiconductors (6)
- Materials for Energy Products (4)
- Optical Switches (4)
- Additive Manufacturing (3)
- Power Electronics (3)
- Sensors (3)
- 3D Printing (2)
- Computing (2)
- MEMS Sensors (2)
- Optical Sensors (2)
- Particle Accelerators (2)
- Synthesis and Processing (2)
- Precision Engineering (1)
- (-) Spectrometers (3)
- (-) Direct Air Capture (2)
- (-) Simulation (2)
![Flue Gas Emissions a Major Source of Atmospheric CO2](/sites/default/files/styles/scale_exact_400x400_/public/2024-03/Flue%20Gas%20Emissions.png?itok=lEpvzK0P)
This invention solves a limitation in the current practice of adding hydroxyl functional groups to the aminopolymer through the use of an alternative synthetic approach. The novelty of our approach is to produce new structurally modified relatives of common aminopolymers (PEI and PPI) as well as new functionalized materials in which the hydroxyl groups are tethered to a carbon in the backbone…
![Schematic of 2P3C setup. Pump laser component is in red while probe laser component is denoted in blue.](/sites/default/files/styles/scale_exact_400x400_/public/2023-05/trace%20gas%20detection%20with%202P3C%20ring-down%20spectroscopy_0.jpg?itok=FcMiekn3)
LLNL’s novel approach combines 2-color spectroscopy with CRDS, a combination not previously utilized.
![Microcapsules offer high surface area and a superior delivery system.](/sites/default/files/styles/scale_exact_400x400_/public/2020-11/Figure1IDEA.jpg?itok=9pdFUISw)
This invention describes a multiple nozzle microfluidic unit that allows simultaneous generation streams of multiple layered coaxial liquid jets. Liquids are pumped into the device at a combined flow rate from 100 mL/hr to 10 L/hr. Droplets are created with diameters in the range of 1 µm to 5 mm and can be created with 1-2 shell layers encapsulating fluid. Droplets created from the system can…
![Plasma wind](/sites/default/files/styles/scale_exact_400x400_/public/2022-08/Plasma%20wind%20.png?itok=RB5iLhMv)
![Graphic of NMR](/sites/default/files/styles/scale_exact_400x400_/public/2020-05/graphic_of_nmr.png?itok=b2_MNmdk)
There are prominent technical challenges arising from spinning a battery on the order of kilohertz as required by magic angle spinning in order to obtain spectral resolution that are addressed and enable operando solid-state NMR. The operando NMR measurement allows for continuous monitoring of the battery components and of potential metastable states that may exist during…
![Intrinsic Use Control](/sites/default/files/styles/scale_exact_400x400_/public/2022-06/Intrinsic%20Use%20Control.jpg?itok=plVEiBwC)
LLNL's method of equivalent time sampling incorporates an embedded system that generates the pulses used to trigger the external circuit and the data acquisition (DAQ). This removes the external reference clock, allowing the overall system clock rate to change based on the ability of the embedded system. The time delays needed to create the time stepping for equivalent time sampling is done by…